Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 16(4): e58825, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38654962

RESUMO

Magnet ingestion can lead to serious health issues, including inflammation, gastrointestinal tract perforation, and even life-threatening complications. Despite legislative actions and numerous reports on the dangers of magnet ingestion in children, it remains a significant public health concern. Physicians must remain vigilant in cases of acute abdomen with ambiguous symptoms or unclear history in young patients. Prompt diagnosis and surgical intervention in case of multiple magnet swallowing are crucial to prevent complications. We present two cases of successful removal of ingested magnetic spheres through laparoscopic appendectomy in adolescents. This study aimed to highlight the technical aspects of the procedure to share the benefits of minimally invasive surgery (MIS) in the management of magnetic foreign bodies (FBs) located in the appendix or cecum.

2.
J Cardiovasc Dev Dis ; 10(11)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37998522

RESUMO

We sought to determine the role of the patient-specific, three-dimensional (3D) holographic vascular model in patient medical knowledge and its influence on obtaining a more conscious informed consent process for percutaneous balloon angioplasty (PTA). Patients with peripheral arterial disease who had been scheduled for PTA were enrolled in the study. Information regarding the primary disease, planned procedure, and informed consent was recorded in typical fashion. Subsequently, the disease and procedure details were presented to the patient, showing the patients their individual model. A patient and medical supervisor equipped with mixed reality headsets could both simultaneously manipulate the hologram using gestures. The holographic 3D model had been created on a scale of 1:1 based on computed tomography scans. The patient's knowledge was tested by the completion of a questionnaire before and after the interaction in a mixed reality environment. Seventy-nine patients manipulated arterial holograms in mixed reality head-mounted devices. Before the 3D holographic artery model interaction, the mean ± standard deviation score of the knowledge test was 2.95 ± 1.21 points. After the presentation, the score had increased to 4.39 ± 0.82, with a statistically significant difference (p = 0.0000) between the two scores. Using a Likert scale from 1 to 5, the patients had scored the use of the 3D holographic model at 3.90 points regarding its usefulness in comprehending their medical condition; at 4.04 points regarding the evaluation of the holograms as helpful in understanding the course of surgery; and rated the model at 1.99 points in reducing procedure-related stress. Using a nominal scale (know or don't know), the patients had self-assessed their knowledge of the procedure before and after the 3D model presentation, with a score of 6.29 ± 2.01 and 8.39 ± 1.54, respectively. The study group tolerated the use of head-mounted devices. Only one patient had nausea and dizziness, while four patients experienced transient eye pain. The 3D holographic arterial model aided in the understanding of patients' knowledge regarding the disease and procedure, making the informed consent process more conscious. The holograms improved the patient's self-consciousness. Mixed reality headset-related complications were rare and within acceptable rates.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...